Field Salinity Water Chemistry Testing

 

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player



 

Field Chemical Analysis

Water sampling follows a certified management system certified complying with the requirements of AS/NZS 5667.1:1998

Downhole profiling of groundwater bodies are available with efficient windows based rugged reader device readers

 

 








Groundwater Field Sampling and Analysis
•Water sampling follows a certified management system certified complying with the requirements of AS/NZS 5667.1:1998.
Sampling Equipment
•We offer water field analysis sampling equipment sourced from Enviroequip
•Planning for the water sampling is to utilize the Micropurge sample pump -76 metre head capacity (Bladder Pump), powered by an air compressor, Draw down meter/dipper, for water level stability measurements during sampling process and a flow cell to direct flow for analysis/sampling techniques.
•Additional sampling equipment is available, as follows,  though the micropurge is highly efficient and provides reliability in sampling techniques.
•Bladder pumps – Passive Sampling Enviroequip
•Purging Air Bottom filling/discharging displacement pumps
•Submersible pump
•Bailers (or disposable bailers)

 

 

 

 

High-rate pumps (Fig. 2) reduce sampling precision due to high-flow effects on volatiles, turbidity, and mixing.

MicroPurge sampling methods (Fig. 3) deliver precise samples with minimal purging; natural aquifer flow brings representative water to the sampling zone with no mixing or excess turbidity.

 

 

 

Bailers & portable pumps (Fig. 1) mix stagnant water, air, and sediment into samples - even after purging 3 to 5 well volumes. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 